Skip to main content

LBR data conduits and Ender Pipe I/O

Mod version shipped with FlammiCraft: 0.51.0

Run data cables inside a bundle

With Little Big Redstone 1.10.0 or newer, craft one LBR Data Conduit from one LBR data cable and one iron nugget. Place it normally or use it on an existing conduit bundle to add it alongside item, fluid, energy, redstone and optional chemical conduits. Its copper-colored surface identifies it.

Join data conduits directly to ordinary data cables and data modems. The whole LBR data network passes through these routes in both directions, including readers, outputs and other compatible addons. Modems are still required at chips and target devices. There are no Insert/Extract settings or port menu for this type; disconnect or reconnect sides with the normal conduit wrench. Disabling either end of a connection breaks the data route.

Existing modem identities and saved transport contents are unchanged. Data conduits count toward LBR's cable limit. Broken or unloaded sections invalidate the route; loaded sections rejoin after the budgeted topology rebuild. Before removing LBR, remove data conduits from bundles as well as their data-network components. Rendering and real-world restart/chunk behavior still need in-game acceptance.

Ender Pipe Network I/O

With Little Big Redstone 1.10.0 or newer, craft Ender Pipe Network I/O from the existing Ender Pipe I/O and an LBR data modem. TDUtilities is not required; existing local components keep their saved format and behavior.

Attach a modem to the chip and another to the redstone conduit bundle, then connect them with data cables, LBR Data Conduits or a mixed route. Configure the installed component's chip modem side and target. One modem supports all 16 colors simultaneously; configure additional components for additional colors on the same target.

  • Output with conduit Extract sends into the conduit network. Fixed sends the selected strength while active; Pass through forwards 0–15. Inactive inputs send zero.
  • Input with conduit Insert reads the raw color channel. Pass through yields 0–15; threshold mode yields 15 for a positive signal at least as high as the threshold. Zero threshold accepts any positive signal.
  • Enable Insert and Extract for both directions at one modem. The color list uses the existing conduit symbols/order. The additional component output is 15 for a valid connection. Changing direction changes component ports; reconnect affected chip wires afterward.
  • The live view distinguishes connected 0, missing conduit --, disabled direction X and an unready network ?; hover text includes value and status.

Sources on a color combine by maximum. The original chip position survives every modem hop. Reads exclude that chip's contributions across all its modems and local outputs while retaining weaker foreign sources. Feedback between different chips remains normal circuit behavior.

Input cards affect the configured Extract color; other colors enter their matching channels directly. Stateful cards run once per port. With multiple origins, strongest contributions receive the filtered result; weaker contributions are capped by that result. Reads do not run the cards again. Output filters do not alter raw-channel reads.

Conduits retain their two-tick cadence. Revoked contributions disappear on the next conduit update and live outputs are recalculated after restart. Data cables and LBR Data Conduits share the data network; item/fluid/energy transport stays with the existing transport conduits.

No chunks are loaded. Missing cable sections or endpoints invalidate the connection. Remove new components from saved chips before removing the integration. Existing components need no migration. Automated checks do not establish rendering, restart, chunk lifecycle or live-load acceptance.