Nucleus Ponder instructions
Mod version shipped with FlammiCraft: 0.556.0
These instructions transcribe the current bundled Ponder scene text. Use the in-game scenes for spatial placement; this text alone does not verify a safe reactor installation.
- Building the Two-Circuit Reactor
- Planning a Reactor Core
- Control Rods and SCRAM
- Nozzles on the Reactor
- The RBMK Steam Loop
- The Lead Tank
- The Steam Turbine
- Linking the Control Room
- Alarms and Paper Charts
- Wiring the Redstone Alarm
- A Stationary Radioisotope Generator
- The Feedwater Pump
- Building the Steam Generator
- Piping the Primary Circuit
- Steam and Feedwater
- Filling and Starting the Plant
- Stopping and Cooling Down
- Power and Emergency Nozzles
- Building the Emergency Cooling Station
- Containment and Accidents
- From Ore to Solution
- Enriching Uranium
- The RBMK
- Reprocessing and MOX
- The Deep Repository
Building the Two-Circuit Reactor
- Start with a 5 × 5 Reactor Casing floor. The finished example is 5 blocks wide, 6 high and 5 deep.
- Build closed walls. All edges and corners must be Reactor Casing.
- Stack Fuel Channels vertically. Here five columns form a cross.
- Put Graphite Moderators in the four marked corners inside the core. Leave one layer above the fuel channels for coolant.
- Close the roof with one Control Rod Drive directly over every fuel column.
- Fit exactly one Reactor Controller in a side wall. Use glass or fittings only on the flat faces.
- Put the Fuel nozzle in the roof of this example. It takes fuel from a pipe.
- Pump spent fuel from Waste to a Spent Fuel Pool. Build this path before adding fuel.
- The reactor heats coolant. Hot Leg sends it to the Steam Generator, Cold Leg brings it back. This loop is the primary circuit. Both nozzles must sit in a side wall within the two layers right under the roof.
- The optional Reactor Heat Port transfers heat to a compatible Create: New Age block in front of it.
- The Steam Generator turns water into steam on a separate side. Continue with the Ponder scene Building the Steam Generator on the Reactor Controller.
Planning a Reactor Core
- Hold the Reactor Sheet and right-click in the air. Choose Two-Circuit or RBMK and enter the outside dimensions.
- In the editor, select a tool and draw one core layer. Whole Column fills that position on every core layer.
- Open Roof. Place a drive above each fuel column on a two-circuit plan. The editor fills in the RBMK roof from the channels.
- Open Review and press Check. Show in grid jumps to the affected cell. Use Parts list to gather the blocks.
- Press Save and wait for confirmation. The plan stays on the item. Test cooling and power on the built reactor.
Control Rods and SCRAM
- Each drive moves a rod above a fuel column. At 100 percent the rods are all the way in and slow the reaction.
- Open MAIN on the linked Control Desk. Scroll up on the rod slider to move the target in by one percentage point per step.
- Move the rods in to lower power and out to raise it. Watch their target, actual position and the power reading.
- SCRAM is the emergency stop. In realistic mode, full travel takes about two seconds on this reactor and eighteen on an RBMK.
- Decay heat remains after SCRAM. Keep primary circulation, feedwater and the steam outlet available.
- The reactor refuses to start if a fuel column is missing its drive.
Nozzles on the Reactor
- A Reactor Nozzle is a fitting you can switch. Right-click it with an empty hand and read the new mode in the action bar.
- On this two-circuit reactor, Hot Leg sends warm coolant to the Steam Generator.
- Cold Leg brings cooled liquid back. The RBMK connections are shown in the Ponder scene The RBMK Steam Loop on the RBMK Nozzle.
- Fuel accepts enriched fuel or MOX. Set up the cooling and the spent fuel outlet before filling.
- Pump spent fuel out through Waste to a Spent Fuel Pool.
- Sneak-right-click a nozzle in any mode except Emergency Hot Leg or Emergency Cold Leg. Set two items as its frequency, in order. Copy the pair into the Reactor slots on the desk and the slots on the Steam Generator.
- A frequency pair belongs to one reactor. The desk and Steam Generator need such a nozzle with the same pair, loaded, within 256 blocks and in the same dimension.
- On a two-circuit reactor, a Relief nozzle shows steam and hisses when the Steam Generator's primary valve opens. The generator handles pressure relief.
The RBMK Steam Loop
- Before starting the RBMK, feed water into Cold Leg. Steam leaves through Hot Leg and goes to the turbine.
- A Create Fluid Tank or Lead Tank collects steam before it goes to the turbine.
- A pump pushes it through pipes to the turbine.
- The Steam Turbine turns it into rotation.
- With the default setting, Exhaust Steam leaves at the top.
- A Radiator with an Encased Fan turns it back into water.
- A second pump brings the water back to the Cold Leg.
- A Steam Vent releases surplus steam into the air. Replace that lost water from a separate supply at Cold Leg.
- By default one vent lets out up to 2400 mB/s.
- Keep water flowing and the steam path open during operation and after SCRAM.
The Lead Tank
- The Lead Tank stores steam and Exhaust Steam; it joins with other Lead Tanks.
- Steam goes in and out through the sides and the top.
- Lead Tanks and Lead Pipes shield radiation like lead.
- With passive condensation enabled by default, steam slowly turns back into water at the bottom of the tank.
- Drive a pump away from the bottom connection to collect the water.
- To keep steam, put a lit Blaze Burner below the tank. In this setup it takes the place of the bottom drain.
The Steam Turbine
- Leave the eight blocks around the center clear when placing the turbine.
- Pipe steam into the bottom or the sides of the casing, never into the shaft ends.
- The rotation comes out of the shaft ends.
- Right-click the turbine center with a Wrench to switch to FE. Connect an FE consumer to the casing. The shaft stops supplying rotation.
- Wrench the center again to restore shaft output. The next example uses rotation.
- By default Exhaust Steam leaves at the top.
- A Low Pressure Turbine on the same shaft takes this Exhaust Steam.
- Pump the Exhaust Steam into a side or the bottom of the low-pressure turbine.
- At equal flow, the low-pressure turbine adds half the first turbine's output with default settings.
- It condenses the steam: water leaves at its top.
- You can put more turbines on the same shaft. Give each a steam supply. A normal turbine takes up to 2,400 mB/s by default.
- Instead, a Radiator turns Exhaust Steam back into water. Steam goes in from any side.
- Point the Encased Fan at the Radiator. A faster fan can condense more Exhaust Steam.
- By default a fan at 256 RPM takes the steam of one turbine.
- The water leaves at the bottom or through a pump.
Linking the Control Room
- Sneak-right-click a nozzle that is not set to an emergency leg. For this example, put a stick in the first frequency slot and redstone dust in the second.
- Open the Control Desk. Put the stick and redstone dust in the two Reactor slots at the top right, in that order. MAIN shows the linked reactor.
- Use MAIN to start, stop or move the rods. PLANT tells you what is holding up startup.
- Copy the frequency to the Physics Desk. In realistic mode, use Core to review the reactor and Power to estimate the supplies for your target load.
- The Reactor Control Panel in the vessel wall has local rod steps, SCRAM and reset. Tab moves between these controls.
- Redstone at the panel triggers SCRAM. The desk's Link tab has separate Redstone Link channels for commands and status.
Alarms and Paper Charts
- Right-click each instrument and give it the same two frequency items as a reactor nozzle.
- Without that link it shows no valid reading.
- A new alarm shows ! in the Annunciator menu. Point at the field or focus it with Tab to read the cause.
- Press Acknowledge alarms at the Annunciator. The linked horn and siren stop sounding.
- An acknowledged cause stays marked ✓ while it is active. If it clears and returns, ! and the sound return.
- The Analog Wall Gauge switches between temperature, pressure and thermal power.
- The server sets its scale.
- Open the Chart Recorder with right-click. Put paper in the left slot and press Record if the recorder is paused.
- By default one page holds 60 temperature and power samples.
- Pause stops sampling. Print page puts the chart in Output, the right-hand slot.
- Take the chart from Output and use it. Move the mouse over the plot or use the left and right arrow keys to read samples.
- A full output pauses the recording. Partial pages keep their reactor across reloads.
Wiring the Redstone Alarm
- Supply a redstone signal from a lever, a circuit or a Redstone Link output.
- Open the alarm with right-click. Select a sound, then set volume, rotation speed and beam length.
- Lever on. The alarm light stays on. The NUKE Siren loops the recording. Muted keeps the light without sound.
- Lever off. The light and NUKE loop stop. Read and acknowledge reactor alarms at a linked Annunciator.
A Stationary Radioisotope Generator
- The Stationary RTG generates FE from a sealed source. Craft its empty capsule from eight lead ingots around a glass pane.
- Under a Create Spout, fill the capsule with one bucket of high-level waste from reprocessing.
- Right-click the RTG to open its menu, then put one sealed source in the source slot.
- Connect an FE consumer to any face. This example shows an Electric Feedwater Pump beside the RTG.
- By default the RTG adds 64 FE per tick to a 64,000 FE buffer and keeps the source.
- The menu shows generation, stored FE, a missing source and a full buffer.
- You can stop generation or take the source out; buffered energy stays usable.
- Breaking and replacing the RTG keeps its source, energy and switch.
- It only runs while loaded and standing still; on a Sable ship it stops making and giving FE.
The Feedwater Pump
- Point the Feedwater Pump from the water supply toward Feedwater In. Connect a shaft at its side.
- At 256 RPM with default settings it moves 1,536 mB per tick through one line and draws 12,288 SU.
- The electric pump has the same flow at the same speed. Connect FE and use the value panel. At 256 RPM it draws 1,024 FE/t by default. Redstone stops it.
- Either Feedwater Pump also moves steam. Use Primary Circulation Pumps for the sealed coolant loop.
- At the linked Control Desk, open PLANT, then Steam side. Compare feedwater arriving with current demand.
Building the Steam Generator
- Build the two-circuit reactor first. Its Hot Leg carries coolant to the Steam Generator and its Cold Leg receives it back.
- Build a 7 by 7 by 7 box out of Pressure Vessel Casing. Keep the edges and corners in casing.
- Inside, place at least one Heat Exchanger Tube. More tubes transfer more heat. Leave the rest empty.
- Fit one Steam Generator controller in a face. Right-click it and set the same two frequency items as on the reactor nozzle.
- Use an empty hand to set this port to Hot Leg In. It receives hot coolant from the reactor.
- Set a separate port to Cold Leg Out. It sends cooled coolant back to the reactor.
- Set this port to Steam Out. Connect it to the steam inlet on the turbine.
- Feedwater In takes water back from the condenser. You can fit up to four Feedwater In ports and four Steam Out ports.
- Fit Relief if you want the primary side to vent. The steam side has a built-in safety valve. Secondary Relief marks where its steam appears.
- Supply FE to Power In for the heaters that build pressure. Reserve a second Steam Out for the cooldown branch before you start.
Piping the Primary Circuit
- The primary circuit is the coolant loop. Drive the pump on Hot Leg with a shaft. It pushes coolant through Lead Pipe into Hot Leg In.
- A Lead Tank divides a leg into two stretches, and each stretch needs its own Primary Circulation Pump. Here the electric pump moves coolant from Cold Leg Out into the tank. Connect FE and set its speed.
- The second stretch runs from the Lead Tank to the reactor's Cold Leg. Its mechanical Primary Circulation Pump is driven with a shaft. All pumps of a leg must push in the same direction.
- Put one Coolant Buffer column on the cold pipe. Use up to five blocks so the coolant has room as it heats up.
- Use a Create pump into the Lead Tank to add cold primary coolant. Keep the circulation pumps running while filling.
- Read the tank with Engineer's Goggles while filling. The circuit seals itself when the displayed missing amount reaches zero.
Steam and Feedwater
- Steam Out sends steam from the generator's water side to the turbine inlet.
- Leave room for all nine turbine blocks. Here steam enters underneath and rotation leaves along the shaft.
- Exhaust Steam leaves the top of the turbine by default. The fan blows at the Radiator, which turns that steam back into water.
- Collect water in the tank below the Radiator. A Feedwater Pump returns it to Feedwater In. Add water to this tank before starting.
- In PLANT, open Steam side to check the water level. This example has one turbine branch. Match your turbine, radiator and return capacity to the planned output.
Filling and Starting the Plant
- Open PLANT at the linked Control Desk. Read the startup status before adding fuel.
- With the reactor cold and in SCRAM, run the primary circulation pumps.
- Fill cold primary coolant through the Lead Tank. The circuit seals once it reaches the fill target.
- Fill the tank below the Radiator with water.
- Run the Feedwater Pump toward Feedwater In. Keep the steam path open. The water side must reach 20 percent.
- Connect FE to Power In to supply the pressurizer heaters.
- Turn on Heaters in PLANT. By default, startup needs at least 132 bar and half the rated primary flow.
- Connect Waste to a Spent Fuel Pool before loading fuel.
- Connect the fuel tank to Fuel and pump fuel into the reactor.
- In realistic mode, use Power at the Physics Desk to estimate steam, feedwater and primary flow for your target load.
- In MAIN, press START. Withdraw the rods slowly and watch flow, pressure and temperature.
Stopping and Cooling Down
- Before startup, put a Smart Fluid Pipe on the second Steam Out. Set its filter to allow an Exhaust Steam Bucket.
- Pump this branch to the Radiator so cooldown steam can bypass the turbine.
- In MAIN, press STOP for a planned shutdown or SCRAM for a rapid shutdown.
- In PLANT, switch Heaters off and check for Heaters off.
- Keep the primary circulation pumps running. The core still gives off decay heat with the rods inserted.
- Keep the steam outlet open and the Radiator fan running. Keep the feedwater pump returning water to the generator.
- If you used STOP and need to open the circuit, press SCRAM in MAIN.
- Under PLANT, wait for Ready to unseal in the Cooldown row. Then press Unseal.
- When the desk confirms Primary circuit unsealed, use the Lead Tank's fill connection to pump out cold coolant for maintenance.
Power and Emergency Nozzles
- Fit Main Power and Reserve Power nozzles in the wall. Connect a separate supply to each.
- Main Power has priority. A sufficient Reserve Power supply can take over. The two inputs do not add together.
- PLANT shows which input is active and how long the control reserve can keep the desk working.
- On the two-circuit reactor these inputs power the controls. Drive or power the primary pumps at the pumps themselves.
- The Emergency Coolant nozzle fills the reactor's spare coolant tank. It can top up a sealed loop that has lost coolant.
- Emergency Spray supplies water for the protective shell around the reactor. After cooldown the same nozzle can drain the water collected inside.
- The backup circuit has its own Ponder scene: Building the Emergency Cooling Station, found on the Reactor Nozzle and the station.
Building the Emergency Cooling Station
- The Emergency Cooling Station is a 3x3x3 block. Build all twelve edges and eight corners from Pressure Vessel Casing.
- Place the Emergency Cooling Station in the middle of one face. It is the controller.
- The other five face centres take Emergency Cooling Ports or casing. You need exactly three ports: one Inlet, one Outlet and one FE Input.
- Right-click a port with an empty hand to change its mode. Here the left port is the Inlet: warm coolant enters.
- The right port is the Outlet: cooled coolant leaves for the reactor.
- The top port is the FE Input. Feed it from a supply that keeps running without the reactor. The station uses 256 FE/t while cooling.
- Fill the unused face centres with casing. The core block inside may stay empty.
- On the reactor, set one Reactor Nozzle to Emergency Hot Leg and another to Emergency Cold Leg. Right-click a nozzle with an empty hand to change its mode.
- Run one Lead Pipe line from the Emergency Hot Leg nozzle to the Inlet.
- Run a second, separate line from the Outlet to the Emergency Cold Leg nozzle. Neither line may branch. The pump is built into the station.
- Sneak-right-click both emergency nozzles and give them the same two frequency items.
- Right-click the station and enter the same two items in the same order.
- Look at the station or a port with Engineer's Goggles. They show Standby when all is right, or name the exact problem and the block at fault.
- When main flow falls below half, the station takes over, if the primary circuit is sealed and filled. While the reactor runs, it drives the rods in until power is at most 20 percent. After SCRAM it keeps cooling while the reactor or coolant is above 80 °C.
- Each takeover during operation uses one of ten switch slots. A slot recharges in ten minutes while the station is loaded and has power. With no free slot the reactor trips, and the station still cools.
Containment and Accidents
- Without cooling, the core overheats.
- If the core overheats while it still has water, a gas called hydrogen can build up around the reactor.
- Build a closed protective shell around the reactor from suitable concrete or lead. This is the containment. Check it under PLANT.
- A closed shell contains steam and gas, so pressure can build inside. Watch containment pressure and keep cooling available.
- The scene hides the shell to show the waste pipe. Pump spent fuel through Waste to a Spent Fuel Pool and let it cool there.
- After cooling, move spent fuel to a Dry Cask or to a Reprocessing Plant.
From Ore to Solution
- Crush Uranium Ore in Create Crushing Wheels. Wear a Hazmat Hood around the ore.
- Pass the Crushed Uranium Ore through the next four stations in order.
- First, a Spout fills the crushed ore with Nitric Acid.
- Second, run it under a Mechanical Press.
- Third, a Deployer adds bone meal to the unfinished item.
- Fourth, press the item again to get Yellowcake.
- Mix the Yellowcake with Nitric Acid in a heated Basin to make Uranyl Nitrate.
- If radioactive liquid spills, use the Geiger Counter to check the area after washing away the visible liquid.
Enriching Uranium
- A Gas Centrifuge separates reactor fuel from the feed solution. Stack several to make fuel usable in a reactor.
- Drive the stack from above at 128 RPM or faster. Seven working stages are needed for the first reactor fuel grade.
- Pump Uranyl Nitrate into the bottom centrifuge.
- Pump Depleted Uranyl Nitrate from another side of the bottom centrifuge into a separate tank.
- Pump the enriched fuel from the top centrifuge into its own tank.
- This example has seven stages and yields 4.30 percent fuel. Twelve stages yield 14.30 percent.
- A higher grade lasts longer at the same power. In realistic mode it can raise power faster at the same rod position. Empty the product tank before changing grades.
The RBMK
- Build the shell from RBMK Biological Shield. Inside, stack fuel and control rod channels.
- RBMK Fuel Channels: graphite with a pressure tube, stacked in columns.
- Control Rod Channels take the rods.
- Water boils inside the RBMK fuel channels and the steam goes straight to the turbine.
- Place an RBMK Upper Shield block in the roof over every fuel channel.
- Put a Control Rod Drive above each Control Rod Channel.
- Use RBMK Nozzles in the shield faces: Cold Leg takes water, Hot Leg sends steam directly to the turbine.
- A Relief nozzle on the RBMK vents steam from the reactor itself.
- Fit the RBMK Control Console in a shield face. It is the controller for this reactor.
- In realistic mode, steam bubbles can raise reactor power. Keep water coming in and steam going out.
- With fuel and neutron flux above 2 percent, the controller warns below 15 percent rod insertion. Flux is the strength of the reaction. The rods are nearly all the way out.
- In realistic mode, full rod insertion on SCRAM takes up to 18 seconds.
- Power can briefly rise at the start of insertion. Keep water and steam moving throughout the shutdown.
Reprocessing and MOX
- A Reprocessing Plant next to a Spent Fuel Pool takes its waste once it has cooled.
- Feed Nitric Acid to the plant and drive it at 64 RPM or faster.
- The plant produces Uranyl Nitrate, Plutonium Nitrate and High-Level Waste.
- Allow only High-Level Waste in the first filter pipe. Give it its own tank.
- Allow only Plutonium Nitrate in the second filter pipe. Keep it for MOX fuel.
- Allow only Uranyl Nitrate in the straight filter pipe. Keep all three outputs separate.
- Send the recovered Uranyl Nitrate back to the centrifuges.
- MOX is an alternative reactor fuel. Feed Plutonium Nitrate and Depleted Uranyl Nitrate into the basin under the Mechanical Mixer.
- Pump the finished MOX fuel into the reactor's Fuel nozzle.
- In realistic mode, move the rods in small steps with MOX and watch the power response.
The Deep Repository
- In a heated Basin, press Sand, an Iron Ingot and High-Level Waste into a Vitrified Waste Canister.
- The finished canister emits radiation while unsealed. Keep it shielded on the way to storage.
- Keep liquid High-Level Waste in a tank until it goes into the heated Basin. A spill on the ground can contaminate the area.
- Build a Bentonite chamber. The Repository Vault must be at Y −32 or lower with default settings.
- Place the Vitrified Waste Canisters inside the Bentonite chamber.
- Close the chamber. Put a Repository Vault in its wall with the back facing the canisters.
- Right-click the vault. It checks its height, the lining and the canisters. Read any problem in the action bar.
- When the check passes, the action bar confirms that the vault has sealed the canisters permanently.
- Sealed canisters stop emitting radiation.