Skip to main content

Neo ECO AE operating workflow

Mod version shipped with FlammiCraft: 21.65.0

Deutsch · Update and export guide

Storage stores resources, Computation supplies crafting CPUs, and Crafting supplies patterns/execution lanes. One large structure does not automatically provide all three roles.

Build and verify a host

In the workstation preview, the extra cooling button switches between the normal and Smart Cooling structure and updates its material list. Reopening JEI or EMI restores that recipe's variant. Rebuilding missing structure parts preserves installed cooling modules in every horizontal orientation and keeps existing energy interfaces as accepted alternatives.

Place the correct controller/tier and confirm orientation. Open its side structure-builder panel and choose length and mirroring. Drag and zoom its integrated 3D preview, scroll the materials and hover the status for missing/reusable blocks, quantities and conflict positions. Resolve conflicts deliberately; the builder does not overwrite them.

Supply materials in your inventory or supported container items and choose Build. Survival construction progresses on server ticks and consumes materials only for successful placement. Interrupted work retains already placed blocks. Preview again after missing items, new obstructions or leaving the session. If another mod rotates a freshly placed block, the builder restores the planned facing; if that fails, it reverts the block without consuming materials and stops. Viewer length/layer controls cycle forward with left-click and backward with right-click.

For nested bags, the outer container must allow extraction and reinsertion of the inner bag. The builder extracts the inner bag, consumes its material and returns it. If reinsertion is refused, the bag returns to the player's inventory; a full inventory drops it beside the player. Locked extractions supply no building material. Put materials directly in your inventory if a container's rules are unsupported.

Connect storage

Replication AE2 Bridge 3.2.0.0.0 or later adds LE4, LE6 and LE9 matrices for Replication Matter. MEGA Cells adds an LE9 MEGA matrix for the same resource. Applied Replicatics Matter uses its own matrices.

The item Digital Singularity matrix stores up to five physical item types without markers, retaining exact quantities beyond the long limit. Mark a resource in the cell workbench to enable its bulk compression chain; its forms then share a type slot. While markers are present, only matching chains are accepted. Occupied markers remain protected until the chain is empty. Existing amounts migrate exactly into the bulk ledger when the cell backend first opens, without transferring items into the network. Other Singularity channels retain their backends and limits. Network-wide power accounting stays in place.

Keep a suitable world backup before the first updated world start: downgrading does not automatically read the new item ledger. Conflicting old and new ledgers reject automatic migration and retain their records; do not delete them or disassemble the matrix.

Form the host with matching tier components, ME interface and power. Insert suitable matrices into physical drives and test one insert/extract. The host panel reflects drive positions and exact resource quantities. Filters, migration and ownership checks still apply. Do not disassemble stocked, pending or quarantined matrices.

In either a storage or computation host, Shift-left-click to move compatible matrices between your inventory and the drives. Hold Shift and the left mouse button and drag across further slots to transfer them in order. Any matrix the destination cannot take stays in its source slot.

For a partitioned ECO storage matrix, the item tooltip shows whether the filter includes or excludes its entries and uses precise or fuzzy matching.

The mod no longer supplies assembly recipes for legacy 16M, 64M and 256M Bulk Item matrices, including with MEGA Cells installed. Existing matrices can still be used and disassembled when empty. Check any saved crafting patterns that produce these matrices. The Data matrix housing for Data Energistics uses two Obsidian Ingots with a Data Crystal between them in the bottom row.

Recover an offline ECO Omni matrix

If the server cannot load data for an existing UUID, the matrix stays unavailable. Back up the matrix and world data. Look for Cannot load ECO Omni storage UUID in the server log, restore the matching Omni storage file from a world backup and reload the world. The file may also be missing for older matrices that were bound while empty.

If the log shows Refusing duplicate ECO Omni storage UUID, another ECO drive already has that UUID mounted. Remove the second matrix. To move the original, remove it from its current drive before inserting it in the destination.

The Storage Network Switch uses a channel and discovers loaded same-dimension hosts. It changes priority but does not pool capacity or migrate contents. Open host retains the original eight-block reach.

IO ports exclude Storage Bus containers by default. Inspect that and Creative Input switches when intended transfers stop. Excluded storage can remain visible in terminals. Unaccepted material remains buffered for retry.

Reattach a lost Infinite Storage domain

If the original controller is missing, run /neoecoae storage_recover <uuid> as an in-game operator with the saved domain UUID. Within five minutes, right-click the formed replacement controller with your main hand. The replacement must be in infinite mode with an empty domain and a complete set of member matrices. Finish active migrations and restores before recovering the domain.

The success message appears after the binding and affected chunks have been saved. The inventory stays under the same UUID. Old controllers and old controller items lose access to the domain, including when their chunks load later. Breaking the replacement controller normally carries the current binding on its drop. If a save fails, check the server log and repeat the command on the same replacement after resolving the error.

When saved member or migration IDs are invalid, the controller logs the issue and preserves the original entries. The affected domain stays blocked until the controller data has been inspected and corrected. Opening the normal-storage restore preview does not assign matrix IDs.

Run crafting

Large reports and graphs may take several server ticks to load. The view accepts only a complete transfer. Closing or changing the menu cancels unfinished encoding. Cycle amounts use the resource's unit, including fluid quantities.

AE2LT can link directly to a standalone workstation by wireless connection. Formed workstations connect through their structure. ECO skips batch learning for processing targets that explicitly declare unlimited input capacity; finite targets of the same provider keep their learned limit. Unknown capacity contracts remain conservative. Larger batches still require their real materials and energy.

Use Save PNG in the crafting report to export the complete material list for the displayed plan. The image is saved in the game's screenshots folder and linked in chat.

Open a cycle in the crafting graph and select Cycle stages to view starting stock, external supply, consumption, production, requested delivery and remaining stock. Large repeats appear as combined stages. Hold Shift for exact quantities. A search without a verified sequence shows that status in the report. Gold identifies proven reusable seed. For ordinary ECO jobs, the CPU can return surplus seed from a completed cycle to the ME network early once no remaining step needs it.

A formed, online, active ECO computation host in the terminal network makes the normal AE2 crafting-status entry open the new ECO page. Its left pane lists network CPUs including native AE2 CPUs, its centre shows materials, and its right pane keeps running steps in first-observed order. Search moves matching materials first: names directly, @ for mod IDs and * for resource IDs. Pause/cancel target the selected CPU; after switching CPUs, details and buttons appear once the server confirms the new selection. AE2 Lightning Tech (Tianshu) CPUs show their amounts and can be paused. JEI and EMI recipe and usage keys work over materials and steps. Right-click a resource for available task actions; local ECO machine details and stop/resume actions remain available. Back returns to the original terminal. Without a functional ECO host, AE2 keeps its own view; lost connection or host validity closes the ECO page. Wireless terminals retain range checks and energy consumption.

Select an ECO CPU with an active job and use the hammer button on the left to open Live Crafting Graph. Hover a material to see the quantities in CPU storage, in progress and queued. Hold Shift for exact amounts. The status line shows when the job is paused, completed or cancelled. If the job is replanned, the graph loads the new structure. Use Back or Escape to return to the CPU list. Native AE2 and Tianshu CPUs continue to use their existing status views.

Form a Computation host with valid matrices, threads and power. Separately form a Crafting host, install Pattern Bus patterns and provide Worker/parallel components. A physical Worker remains one execution lane; exchange multipliers do not create physical machines.

Request a small terminal craft, review the plan, select a CPU and confirm. If inputs are missing, Bookmark missing in the crafting report adds exactly the shortages of the displayed table as EMI favorites (JEI bookmarks without EMI), including plans from the regular AE2 planner. Follow expected outputs and their return route before increasing batches/overclocking. An optional Crafting Energy Interface occupies its designated casing position behind the controller beside the interface and supplies FE without AE fallback; the ME connection remains necessary.

Running crafting jobs block changes to overclocking and active cooling. The controller panel explains when a change is refused.

Without MEGA Cells, the Large Integrated Working Station Casing recipe no longer needs a 64M ECO storage component. The MEGA Cells variant still requires its 64M component. Check saved crafting patterns against the active recipe when the pack supplies its own recipe.

Recover blocked FX work

Standalone workstations save fractional energy payments even before they fund one complete progress step. The same recipe resumes with that payment after reload. A different recipe or changed recipe costs do not inherit it. Blocked outputs retain paid progress without charging again. Formed workstation batches keep their own separate progress.

If an ECO cell save fails, its pending persistence obligation remains in memory and receives fair retries. Repeated attempts for the same outstanding obligation do not repeat its initial error message. Fix the cause shown in that first message; silence alone does not prove a successful save. Shutdown still reports obligations that could not be saved.

Since 21.46.0, an FX worker record that cannot be decoded completely stays saved unchanged. Its lane remains occupied and neither processes nor refunds the readable subset. The server log identifies the blocked worker position. Restore the matching resource mods/datapacks and reload the world; only a successful read removes this block. For damaged data, inspect a suitable backup. The worker can be carried as a block item with its retained record. /neoecoae clear_fx_workers still deliberately discards the affected contents and is not a recovery step. This update cannot reconstruct entries lost earlier.

Automated save/reload and container tests check these rules. Gameplay acceptance still needs the actual bag mods, world restart and replacement of a blocked worker.

Large integrated working station

Place processing patterns in the Large Integrated Working Station Smart Pattern Bus. You can submit jobs for enabled recipe families before installing the matching upgrade card. The workstation saves the accepted inputs and shows when the first job is waiting for its card. Insert the indicated card to continue. Later jobs stay queued.

To abort a waiting job, return its materials from the task list. Any inputs the ME network cannot accept stay in the workstation until storage is available. Waiting jobs and outstanding returns survive a restart.

Coolant stocking and recovery

In neoecoae-common.toml under [storage], smartCoolingRefillThresholdPercent sets the buffer percentage below which Smart Cooling tops up (1–100, default 100). outputTransferIntervalTicks delays small storage interface exports (1–20, default 1). A resource type at or above outputFlushThreshold can transfer early (default 64 in raw AE2 units). Waiting stock stays in the host and the interface still processes up to five resource types per tick.

In a formed Large Integrated Working Station, the AE button next to the guide switches the power priority between the FE input buffer and the ME network (AE). It applies to processing, preheating and Smart Cooling. If the preferred source cannot cover a step, the station uses the other source when it can supply more power.

The Smart Cooling Controller replaces the upper center casing directly behind the workstation controller. The ordinary coolant inlet stays in the lower layer. For an older build with the Smart Cooling Module in that inlet slot, empty its buffer and record the target temperature before upgrading. Then move that block to the upper layer and install a regular inlet below. Move any energy interface from the upper rear center to a side position in the same row.

The controller has a 16,384,000 mB buffer. The regular inlet fills it from pipes. A coolant marker limits the inlet to that fluid and enables automatic ME refills every 200 loaded server ticks. Set the marker in the right slot with a fluid container or through JEI/EMI. Left-click with an empty cursor to clear it. The left slot shows real stock. When the mark changes or is cleared, old stock returns to the ME network first. Rejected stock stays in the buffer. For overheat recovery, supply Cryotheum Solution to the inlet or mark it for ME supply.

The 20-tick stocking rules below apply to ordinary input hatches with a Network Pull Card.

With temperature control enabled, the large integrated workstation generates heat once per paid overclocked working tick. New server configurations enable largeWorkstationTemperatureEnabled by default. Existing values in neoecoae-server.toml still apply.

Equivalent workstation tasks in the same identified crafting job can refill across other unstarted recipes whose inputs are fully owned. If simulated power cannot fund the larger step, the existing task stays at its current size. Paid work, AE credit, FE remainders and pending refunds remain intact. After an update, check saved jobs for progress and returned outputs; these flows still require gameplay acceptance.

A Network Pull Card gives an input hatch a marked-fluid slot above its real buffer. Marking consumes no fluid. Use the gear to set target buckets, including fractional values. The hatch replenishes every 20 ticks from its connected powered/channelled ME grid.

Lowering a target or changing fluid returns excess/old stock where possible. Unaccepted remainders stay buffered and block new pulls. Removing the card stops stocking without deleting contents. Filter/ghost slots are not actual storage.

Read the overview's full unlimited-mode conditions before expansion. Capacity loss can cancel running or restored jobs. Finish work before structural changes. For failures inspect structure, power, channel, matrix/filter, machine output and return path. A planning budget limit is unresolved search, not proof of missing resources. Source checks do not replace large-order, restart and recovery acceptance.

Controls and execution rules from 21.50.0

Host and status screens use cards for capacities, queues, temperature and energy. Hold Shift for exact numbers. The left terminal-style button changes the AE2 height preference; all three lists and their scroll areas stretch to the available GUI height. Processing steps have row-wide progress; workstation tasks blocked before their first push can appear as waiting. Right-click opens the existing task actions, including stop/resume and opening a resolved machine. Server permissions, job identity, world and loaded-chunk checks still apply; missing chunks are never loaded. The JEI/EMI structure preview can cycle registered upgrade-card models without installing a card in the world.

FT parallelism is compared with the current FX batch limit, including overclock and network multipliers. The exchange multiplier scales both sides. Accepted batches in a logical exchange network with at least two switch hosts execute in one tick. Coolant still limits effective overclock; energy, input/output capacity and blocking mode remain prerequisites. These rules can change throughput and the displayed overflow tier relative to the previous fork. Verify a small order through actual delivery before changing a running setup.

The cell-priority view configures individual physical cell slots on ECO and supported addon drives. Changing priority affects future transfer order and does not move existing contents. Check host priority and cell priority separately if a transfer selects an unexpected destination.

Crafting cards and an installed ME Requester use ECO planning when the grid enables it and a functional ECO computation host is available to that request. Otherwise the original planner remains responsible. When ECO returns no executable plan, because inputs are missing, the network changed while calculating or the calculation failed, AE2 plans the same order at once, so the order is no longer lost. The order then skips ECO for 5 seconds, doubling up to 30 seconds on further failures, and AE2 plans it meanwhile; pattern changes and recipe or tag reloads end the pause. A calculated order is only complete after actual output delivery.

Right-click the Smart Cooling Controller to open its panel. Set the target from 0 to 99 with the numeric field or minus/plus buttons. Click changes it by 1, and Shift-click changes it by 10. Status, buffer and consumption appear below. With temperature control enabled, it maintains the target while idle as long as power, coolant and byproduct output space are available.

After completion or cancellation a CPU may still be returning materials. Returns are bounded per tick and across CPUs sharing a grid; allow further ticks with connected storage. Rejected resources stay in the CPU, which cannot accept a new order until they are returned. An uncertain transfer failure is saved and never automatically replayed. Do not delete its error data or force a retry: reconcile the receiver inventory, CPU contents and server log for that transfer first. Restarting does not clear the stop.

Local common settings

neoecoae-common.toml complements the existing client/server files. [keyReuse].enabled defaults to true and reuses immutable resource keys without additional data; components and NBT retain their meaning. It does not migrate inventories. [devTools].enabled defaults to false in production. Restart the client after a visibility change; multiplayer servers must enable development tools separately. Commands under /neodev help require permission level 2. Generators and FE workloads can create resources and consume actual stored grid energy. Enable them only in a dedicated test network.

Existing storage and CPU ledgers remain in use. Caches rebuild automatically; no manual data migration, clearing or setup is required. Earlier ledger-update precautions still apply. GUI scales, multiplayer, real FT/FX orders, ME Requester and save/reload with outstanding returns still require gameplay acceptance. Automated checks prove neither these cases nor an MSPT improvement.