Create Electro Energetics
Mod version shipped with FlammiCraft: 1.21.1-1.7.0
This Create add-on simulates electrical networks with voltage, current and transmission losses. An alternator converts rotation into electrical power. An electric motor uses electrical power to drive machinery. Use an FE converter to connect blocks that use Forge Energy.
Place and check wires
- Hold a filled wire spool and right-click the first terminal. The spool glints while a starting point is selected.
- Right-click the second terminal to place the wire. Sneak and right-click to clear your selection.
- Use a voltmeter to measure the voltage between two points. An ammeter wired in series measures the current.
Hold a matching spool or loose wire material in your main hand and aim at a placed wire within reach. Hold either Alt key or Create's configured Alt modifier. Scroll down to shorten the wire or up to lengthen it. The copper wire and the glass section of a Hanging Glass Insulator can each be adjusted with their own matching material.
Select a new starting point after changing dimensions. Spool selections saved by older versions also need to be selected again.
If the connection is rejected, check that both ends are valid terminals and that the wire fits within the configured length for its type. If a wire breaks, check the current and the components' ratings before replacing it. The in-game Ponder scenes demonstrate circuits, meters and electric railways.
Breaking an electrical panel in Survival also drops its installed components. A circuit breaker keeps its configured current rating on the dropped item.
Import saved inductor currents
The stable upstream 1.1.0 through 1.1.4 branch uses a different direction for saved inductor currents than this fork. Earlier builds containing inductors before the solver rewrite also use the old direction. Values already saved with the new solver or converted by an addon must not be negated again. The version number alone cannot identify the convention.
Unmarked values remain unchanged when loaded and saved. New inductors and explicitly confirmed values receive a saved convention marker. Ambiguous old values are not automatically marked.
For old values confirmed against the original mod JAR and world backup, without a previous addon conversion:
- Back up the world before upgrading. Establish the origin of each affected inductor on a copy first. Migration cannot undo simulation that has already run with the wrong direction.
- Run
/tick freeze. The following commands require permission level 4 and act in the command source's dimension. - Inspect the record with
/cee device_data x y z. - For a confirmed old value only, run
/cee inductor_current x y z legacy_1_1. This negates the current once and marks its convention. For an already correct or addon-converted unmarked value, use/cee inductor_current x y z currentinstead; it keeps the current. - Inspect the record again, run
/save-all flush, then/tick unfreeze. Repeating migration leaves a marked value unchanged.
Both changes are blocked while WWPG is installed, so CEE and WWPG cannot both convert the value through this command. Do not remove WWPG to bypass this guard. Establish an upgrade path for the WWPG version in use. Its announced 1.2 conversion is not yet available as publicly inspectable code. Values of unknown origin remain unmarked and unchanged. There is deliberately no automatic world-wide conversion.
Requirements and settings
Use Minecraft 1.21.1 with Java 21, NeoForge 21.1.251 or later and Create 6.0.10 within the 6.0 series. Install the same mod version on both server and client.
Connect an FE cable or machine to the converter's rear face. In source mode the converter accepts FE and supplies the electrical network. In the other mode it takes power from the electrical network and supplies FE.
electroenergetics-server.tomlcontrols wire lengths, FE conversion, overload behavior and electrocution, among other settings. When electrocution is enabled, the mod checks for wire contact every four game ticks. Very brief contacts between checks can go undetected. Detected contacts continue to load the circuit between checks.electroenergetics-client.tomlcontrols wire rendering, including view distance and Flywheel rendering. If you see visual artifacts around cables or overhead contact lines, setdisableFlywheelWireRendering=trueand restart the client to switch wire renderers.
Mounting overhead lines
Click the underside of a ceiling or a side-mounted Pole Mount with the Catenary Holder. Place the holder directly below the ceiling point or at the same height in front of the bracket, up to eight blocks away. Use a temporary placement block above the track if needed. Sneak-click to cancel selection. Removing the selected support hides the arm.
Add other supports to the electroenergetics:pole_mount_supports block tag.