Operating AE2 Reforged
Mod version shipped with FlammiCraft: 19.68.0
Since 19.61.0, AE2 initializes the grid nodes of each chunk during its level tick as soon as the chunk can tick block entities. AE2 rebuilds connections from existing cables and devices when loading. After updating, start the client and server with the same version and check access to ME storage from an affected terminal.
Delete missing cell contents by command
AE2 Reforged replaces AE2 on both sides, retains mod ID ae2 and requires GuideME. Use its bundled guide for structures and progression. Match client/server builds; source documentation is separate from installed-world acceptance.
Requirements and upgrade
TDLibrary 0.59.0 or newer, including LDLib2, is required. Inventory indices and LDLib inventory marks are native to the AE2 fork. The old external crafting-tree API integration is removed; the native crafting display remains available. Existing ME data retains its IDs.
Features transferred from older TDAE2Additions releases use the ae2 namespace. Convert any former addon IDs still present in a world before upgrading. Back up the world and verify the converted devices, patterns and settings in a test copy. If TDAE2Additions is installed, use version 1.21.0 or newer.
Build and verify a small store
Obtain Fluix/Certus materials and processors using installed recipes. Connect power, cable, ME Drive and a terminal; use an Energy Acceptor for supported external power and a cell for buffering. Insert a matching item/fluid storage cell. Insert and extract one item manually before connecting automation.
With channels enabled, an ordinary controllerless grid is limited to eight. Cable and dense cable capacities differ; adding a controller does not fix a bad channel route. Storage Buses expose external inventories, Import Buses pull resources in and Export Buses send them out. Configure filters and priorities to avoid loops.
Since 19.64.0, Storage Buses use the last listing to check for missing items when the slot index is enabled and the inventory has no index of its own. From 19.65.0, this shortcut also applies to fluids on the built-in NeoForge storage adapters. An update from the connected block or a transfer through the bus invalidates the shortcut immediately. Without an update, a newly added resource may be missed during extraction and insertion preference checks until the next scan or until the listing is more than 20 game ticks old. The terminal display continues to follow the scan. Direct extraction requests still check fluids hidden by the extractable-only filter.
Request autocrafting
Encode a crafting or processing pattern. Put crafting patterns in a Pattern Provider next to Molecular Assemblers. Processing patterns go to the actual machine input and must describe its real returned outputs. Return products into the same ME network. Supply a Crafting CPU with sufficient storage; co-processors improve parallel work rather than storage.
Request a craftable item from the terminal, review amount, missing resources, plan and CPU, then confirm. Follow CPU status. A waiting output usually needs inspection of machine power, byproducts, output quantity and return route. A processing pattern cannot validate a machine's real recipe; cancellation does not undo external machine buffers.
Export Buses, Stock Export Buses and other automatic requesters with a Crafting Card keep a running calculation when only the requested amount changes; only a different item cancels it. Surplus output goes into network storage. Orders with missing ingredients wait until network stock of one of those ingredients increases. A safety retry after three minutes also covers external storage. Changing bus settings ends the wait. The affected bus slot's tooltip explains the wait. Other failures retain short retry delays, and a plan kept for a busy CPU is still offered on every bus tick.
Use fork tools
Since 19.66.0, the Pattern Encoding Terminal fetches one blank pattern from ME storage when encoding or transferring a recipe through EMI or REI with an empty pattern input. After consuming the last blank, it tries to keep one replacement ready. An occupied pattern output or an input that already holds patterns does not cause another extraction. Refills require a live connection, extraction permission and normal terminal energy; an empty network stock leaves the input empty. Existing local blanks remain usable. Hosts sharing this encoding menu use the same behavior; wireless and recipe-viewer interaction still require test-world acceptance with matching client/server builds.
Energy cells remain available as network power providers when a request is below their minimum transferable amount. The AE2 guide can also be placed in chiseled bookshelves. Source tests do not establish in-game acceptance of these behaviors.
An optional refill failure leaves the completed encoded pattern in the output. If a storage or addon callback changes the pattern input during extraction, its existing items are preserved. An extracted blank that no longer fits, or cannot be placed because the menu has closed, returns to the player inventory and drops on the ground if that inventory is full. Regression tests cover these callback cases; they do not establish in-game acceptance with every external storage.
Manual favourites persist per world/server. Confirmation/CPU heights are adjustable. Filter Terminal edits supported device filters under server checks.
The EMI plus button fills the 3×3 grid in the Crafting Terminal and Wireless Crafting Terminal with available ingredients from the player inventory and the ME network. The result stays in the output slot until you take it. EMI's craft hotkeys take the result directly to the cursor (once or up to one stack) or to your inventory (once or as often as space and ingredients allow).
Crafting Tree shows dependencies; Crafting Time estimates depend on observed work and are not deadlines. The craftingTime.showChatMessages setting can mute messages on either side.
Crafting Tree allocates stored intermediates once across its branches. Further crafting uses the remaining stock; extra output from recipe batch sizes does not change the amount actually taken from storage. Batch surplus remains available to later branches and is tracked separately from initial stock. Reusing it does not add crafting batches or raw-material demand.
The diagnostic terminal is currently ae2:diagnostic_terminal. It lists invalid patterns in loaded network sections, not valid recipes with missing stock. Respect incomplete-scan warnings; extracting a finding changes its provider and requires space/permissions.
Use ae2:network_card on a cable/tunnel, search endpoints and review New input, Bind / copy, Unlink or Rename before confirming. Sneak-use in air switches to settings copying; select a source while sneaking, choose two corners, inspect matching devices and apply. Imports can consume upgrades; unloaded/changed/denied targets are skipped. Failures can leave partial changes.
Memory Card and Network Card imports keep already matching upgrades installed, even with a full player inventory. Only actual excess cards are returned and can be dropped if no space is available. Missing cards come from the player inventory or Network Tool.
Network Card, diagnostics, Stock Export Bus and Advanced IO Bus now belong to AE2 Reforged. Do not assume automatic migration from former addon IDs.
ME-linked Color Applicator
Craft a Color Applicator with one Wireless Booster in any arrangement to add an ME link. Charge, stored colors, cards, settings and custom name are preserved; the upgrade does not occupy a card slot. Insert the upgraded tool into a Wireless Access Point's linking input and collect it from the output. Linking again replaces the network target.
The upgraded tool always offers all 16 colors and cleaning. Colors change only by holding the mouse wheel modifier key (Shift by default) and scrolling, to the next or previous color depending on direction, wrapping at both ends. Right-click never changes the color, with or without a target or while sneaking. The color picker and offhand cable coloring remain available. An applicator without ME link only scrolls through its stored colors; a dye and a paintball of the same color count as one color. The selected color stays selected when its supplies run out. Local supplies take priority over ME storage. Cleaning uses one snowball, falling back to 1000 mB of ME water. ME material selection prefers ordinary paintballs, then dyes, then luminous paintballs.
Each application costs 100 AE, plus a distance-based wireless surcharge when obtaining ME material. There is no continuous inventory drain. ME access needs a loaded linked network and an active access point in range in the same dimension, with channels and extraction permission. The action bar reports failures; local supplies remain usable without a wireless connection.
Ctrl + right-click opens the existing crafting amount dialog for the selected color with 100 additional items preset. An offered ME crafting pattern and crafting permission are required. Cleaning prefers craftable snowballs; if only water is craftable, the preset is 100 buckets (100,000 mB). Check the displayed resource and unit, then plan and confirm. Products enter ME storage for later use. The shortcut never paints a target and charges only the wireless surcharge when opening the dialog, not the 100 AE painting cost. Back or cancel returns to the game.
A shortcut hint appears above the hotbar for three seconds after attempting to apply the selected color, only when the connected ME network offers a matching crafting pattern and crafting access is allowed. Holding the tool alone shows no HUD hint. The shortcut also remains in the tooltip. If an application fails after extraction, the material stays in the tool as a visible, persistent reserve for a later matching use. Partial water extractions are preserved and topped up. Check compatibility of the new item components before downgrading a world.
Source tests and builds are separate from manual test-world acceptance, including HUD layout, recipe viewers, multiplayer and save/reload with matching client/server builds.
Amounts, settings and failures
Exact large-amount planning retains intermediates, byproducts and task counts beyond long limits. External inventories, addon APIs and physical transport still impose their own limits. Component variants remain distinct.
Amount-field formulas apply the existing power limits to both signs: an exponent of at most 30 and an absolute base of at most one billion. An intermediate result above that base limit cannot be raised to another power. Automated checks for upgrade imports, tree stock and formulas remain separate from in-game acceptance.
Settings use config/ae2-common.toml, config/ae2-client.toml and world serverconfig/ae2-server.toml. Legacy Tree/Time imports preserve migrated backups; keep them for worlds not yet opened. AppMek chemical storage needs standalone Applied Mekanistics and Mekanism.
For missing access inspect power, channels, loaded grid, cell type/capacity, filters/priorities and security. Operators can inspect /ae2 terminalworkers. Do not use test-world/spatial mutation commands as ordinary troubleshooting. Verify storage, crafting, save/reload and addon interactions separately in a test world.
Since 19.64.0, energy cells with free capacity remain eligible for charging when they reject a tiny leftover offer. An automated test covers a regular and a dense energy cell. In a test world, check that continued power input charges the second cell after the first fills.